check the residual DC voltage with a volt-

meter. Then you may work on the termi-

nals. See chapter 2.1.

· Always disconnect the PV generator side

first by opening the PV generator switch;

then interrupt the grid connection by iso-

lating (switching off) the corresponding

grid fuse!

· Never disconnect the PV generator by

pulling out the Tyco Solarlok connectors

under load. Otherwise a powerful electric

arc might damage the connectors. The

damaged connectors then have to be

replaced!

· If your PV system does not have a PV

generator switch, interrupt the grid con-

nection by isolating (switching off) the

corresponding grid fuse first. A fault will

then be recorded in the fault memory

of the Solar Inverter, however.