Instructions for the installer

35

6.2 Fitted installation (module only)

MEASUREMENTS FOR FITTED INSTALLATION

MODEL

MATERIAL

HEIGHT

MC30RA

NOT COMBUSTIBLE

A

310 mm

B

150 mm

COMBUSTIBLE

A

320 mm

B

200 mm

A rubber cap is supplied (

A) that must be removed if the appliance

is installed on a trolley as illustrated in the figure to the side.
If the product is embedded in a masonry compartment do not
remove the cap or provide an appropriate means for the outlet.

FRONT CROSS-SECTION

VIEW

SIDE CROSS-SECTION

VIEW

DISTANCE IF
SIDE WALL PRESENT

HOLE FOR REAR
GAS CONNECTION

POSSIBLE BOTTOM COMPARTMENT

DISTANCE IF REAR

WALL PRESENT

HOLE FOR GAS

CONNECTION IN

PRESENCE OF REAR

WALL

HOLE FOR REAR
GAS CONNECTION

A