Check the topology gui for any link errors, Quiesce i/o on the link, Check to see if the switch has been reset – Sun Microsystems 6900 User Manual

Page 98: Check the power going to the switch, Sun proprietary/confidential: internal use only

background image

78

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

TABLE 7-1

lists the switch events for Sun StorEdge network FC switch-8 and switch-

16 1 Gbit switches.

TABLE 7-1

Storage Automated Diagnostic Environment Event Grid for 1 Gbit Switches

Component

EventT

ype

Se

verity

Action

Description

Note:

T

e

xt

within

quotation

marks

(“

“)

is

e

xactl

y

as

it

appear

s

o

n

the

Event

Grid.

Action

Required

port
statistics

Log

Yellow

Y

“Change in port statistics on
switch

diag156-sw1b

(

ip=192.168.0.31

)”

The switch has reported a
change in an error counter.
This could indicate a failing
component in the link.

1. Check the Topology GUI

for any link errors.

2. Quiesce I/O on the link
3. Run linktest on the link

to isolate the failing
FRU.

chassis.
fan

Alarm

Yellow

Y

“chassis.fan.1 status
changed from OK”

None.

system_
reboot

Alarm

Yellow

Y

The uptime of the switch
was less than the previous
uptime of the switch. This
could indicate that the
switch has been reset either
by a user or by the loss of
power.

1. Check to see if the switch

has been reset.

2. Check the power going

to the switch.

chassis.
power

Alarm

Yellow

“chassis.power.1 status
changed from OK”

This event monitors
changes in the status of the
chassis’ power supply, as
reported by the SANbox
chassis status.

None.

chassis.
temp

Alarm

Yellow

“chassis.temp.1 status
changed from OK”

This event monitors
changes in the status of the
chassis’ temperature supply,
as reported by SANbox
chassis status.

None.