Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
enclosure
QuiesceStart
Quiesce has started on a
Sun StorEdge T3+ array.
controller
Topology-
Red
Y
’The Sun StorEdge T3+
array has reported that a
controller was removed
from the chassis.
Replace the controller
within the 30-minute
power shutdown
timeframe.
disk
Topology-
Red
Y
The Sun StorEdge T3+
array has reported a disk
has been removed from
the chassis.
Replace the disk within
the 30-minute power
shutdown timeframe.
interface.
loopcard
Topology-
Red
Y
The Sun StorEdge T3+
array has reported that a
loopcard has been
removed from the
chassis.
Replace the loopcard
within the 30-minute
power shutdown
timeframe.
power
Topology
Red
Y
The Sun StorEdge T3+
array has reported that a
power cooling unit PCU
has been removed from
the chassis.
Replace the PCU within
the 30-minute shutdown
timeframe.
controller
State
Change+
The status of the
controller has changed
from disabled to ready-
enabled.
disk
State
Change+
The status of the disk has
changed from fault-
disabled to ready-
enabled.
interface.
loopcard
State
Change+
The Sun StorEdge T3+
array has reported that a
loopcard has been
replaced or brought back
online.
volume
State
Change+
The status of the LUN in
a Sun StorEdge T3+ array
has changed from
unmounted to mounted
and is now available.
TABLE 8-1
Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array
Component
Event
T
ype
Se
verity
Action
Description
Action