Virtualization Engine References

161

Sun Proprietary/Confidential: Internal Use Only

050

An attempt to write a value into
nonvolatile storage failed,
perhaps because a hardware
failure, or one of the databases
stored in Flash memory could
not accept the entry being
added.

• Clear the SAN database.
• Cycle power to the
virtualization engine.

051

The virtualization engine cannot
erase Flash memory.

• Replace the virtualization
engine.

53

The cabling configuration is
unauthorized.

• Check the cabling. Ensure the
server and switch connect to the
host side and the storage
connects to the device side of the
virtualization engine.
• If necessary, clear the SAN
database.
• If necessary, cycle the
virtualization engine power.
• If necessary, import the SAN
zone configuration.

54

The cabling configuration is
unauthorized.

• Check the cabling.

57

Too many HBAs are attempting
to log in.

• Check the cabling.

60

The node mapping table was
cleared using

SW2

.

• No action required.

62

SW2

settings are incorrect..

• Correct the

SW2

setting.

• Cycle the virtualization engine
power.

126

Too many virtualization engines
in the SAN.

• Remove the extra
virtualization engine.
• Cycle the virtualization engine
power.

130

The connection between
virtualization engines is down.

• Correct the problem.
• Cycle the power on the
follower virtualization engine.

TABLE A-4

Virtualization Engine Service Codes (Continued)—0 -399 Host-Side Interface Driver Errors