beautypg.com

Connections, Basic connection for monitoring or recording – Sanyo VCC-3944 User Manual

Page 9

background image

8

English

CONNECTIONS

Basic connection for monitoring or recording

The peripheral devices (VCR, monitor, lens, etc.), AC
adaptor and cables are sold separately.

1

Make the video signal connection between the camera
and the monitor or time lapse VCR.

2

Connect the power supply.

• If using a commercially-available 24 V AC adapter,

always be sure to connect the ground wire (18AWG or
higher) to the ground terminal. (Figure 1)

• If using a 12 V DC power supply, make the connections

as shown in Figure 2.

Note:

• In order to avoid any problems with the camera and the

power supply, take sufficient care to ensure that the
polarities are correct when connecting the power supply.

3

Insert the plug of this power cord into a wall outlet.

The POWER indicator (A) will light. Adjust the picture on
the monitor using the Brightness and Contrast controls etc.

Coaxial cable type and maximum length

• Cable type RG-59U (3C-2V), 250 m maximum.

• Cable type RG-6U (5C-2V), 500 m maximum.

• Cable type RG-11U (7C-2V), 600 m maximum.

CAUTION:

• The RG-59U type cable should not be run through electrical

conduits or through the air.

• Use CCTV/Video-grade coaxial cable.

GND AC24V

DC12V

GND AC24V

DC12V

(Video signal connections)
: VIDEO IN
: VIDEO OUT

(A)

1

24 V AC connection

Figure 1

Figure 2

12 V DC connection

L5AF2_US.book 8 ページ 2002年12月20日 金曜日 午後1時48分