beautypg.com

Settings – Sanyo VCC-3944 User Manual

Page 11

background image

10

English

SETTINGS

Iris function setting

1

1

1

1

This should normally be set to the down (AI) position.

Use a manual or fixed iris lens and set the lens aperture to the
shortest F stop. Set the switch

1

to the up (EI) position.

Note: Please refer to the specifications for dynamic range of

the electronic iris.

CAUTION:

• The electronic iris is suitable for normal indoor use. When

the switch

1

is set to the up (EI) position, do not use an

auto-iris lens.

• If used under fluorescent light, the image may flicker. In

such a case, change to incandescent lighting or set the
switch

1

to the down (AI) position and use an auto-iris

lens.

• When shooting bright subjects, pay attention to the light

angle in order to avoid or minimize the smear phenomenon
effect.

When using an auto-iris lens (for indoor/
outdoor use)

Set the switch

1

to the down (AI) position.

CAUTION:

If conditions are outside the electronic iris operation range or
more than the maximum illumination, it will cause saturation of
the CCD. In that case, use a manual iris lens.

Gain up setting

2

2

2

2

Switch

2

should normally be set to “NORM”. If the monitoring

location is dark and you would like to increase the luminance
(brightness), set switch

2

to “HI”.

Note: If switch

2

is set to “HI”, the images from the

monitoring location will become brighter, but
interference may become more noticeable.

AI

EI

NORM

HI

L5AF2_US.book 10 ページ 2002年12月20日 金曜日 午後1時48分