Sanyo CL1852 User Manual
Page 6

3
(2) Indoor unit
KS1251
Outdoor unit C1251 / CL1251
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are
Cooling: Indoor air temperature
80°F D.B. / 67°F W.B.
Outdoor air temperature 95°F D.B. / 75°F W.B.
Performance
Cooling
Capacity
kW
3.46
11,800
Air circulation (High)
ft
3
/min
330 (9.35)
Moisture removal (High)
Pints/h
2.2
Electrical Rating
Cooling
Available voltage range
V
104 – 126
Running amperes
A
10.9
Power input
W
1,200
Power factor
%
96
SEER
BTU/W
10.2
Compressor locked rotor amperes
A
60
Features
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
ON / OFF 12 hours, 1-hour OFF
Fan speeds
Indoor / Outdoor
3 and Auto / 1 (Hi)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter
Washable
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
lb. (kg)
1.76 (0.8)
Refrigerant control
Capillary tube
Operation sound
Indoor: Hi / Me / Lo
dB-A
41 / 38 / 34
Outdoor: Hi
dB-A
48
Refrigerant tubing connections
Flare
Max allowable tubing length at shipment
ft. (m)
25 (7.5)
Refrigerant tubing
Narrow tube
inch (mm)
1/4 (6.35)
diameter
Wide tube
inch (mm)
1/2 (12.7)
Cooling
Voltage Rating
115V
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions
Height
inch (mm)
10-5/8 (270)
21-1/4 (540)
Width
inch (mm)
31-11/16 (805)
31-1/2 (800)
Depth
inch (mm)
6-31/32 (177)
11-13/32 (290)
Package dimensions
Height
inch (mm)
9-13/16 (249)
23-31/32 (609)
Width
inch (mm)
33-21/32 (855)
38-5/8 (981)
Depth
inch (mm)
13-5/16 (338)
16-3/16 (411)
Weight
Net
lb. (kg)
17.6 (8.0)
75.0 (34)
Shipping
lb. (kg)
22.0 (10.0)
83.8 (38)
Shipping volume
cu.ft (m
3
)
2.51 (0.071)
8.67 (0.246)