beautypg.com

10 acoustics emissions, 11 electromagnetic immunity, Acoustics emissions – Seagate SV35.5 SERIES SATA ST31000525SV User Manual

Page 20: Electromagnetic immunity

background image

14

SV35.5 Series SATA Product Manual, Rev. C

2.10

Acoustics emissions

Drive emission of sound is measured consistent with the ECMA-74 and its referenced standards. Testing is
conducted at room temperature (approximately 25 degrees C). Emission levels are reported as the total
A-weighted sound power levels for, steady state, idle and active (seek) modes of operations.

[1]

During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may
increase acoustic and power to operational levels.

Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this pro-
cess is the use of the absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to
discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone
ratios according to Annex D of the ECMA-74 standards.

* Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies.

2.11

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 5:

Drive A-weighted Sound Power Levels (SWL, BA)

Idle

[1]

Seek

1000 and 500 GB model

2.7 bels (typ)

2.9 bels (max)

2.8 bels (typ)

3.0 bels (max)

250 GB model

2.5 bels (typ)

2.8 bels (max)

2.6 bels (typ)

2.8 bels (max)

Table 6:

Radio frequency environments

Test

Description

Performance level

Reference standard

Electrostatic

discharge

Contact, HCP, VCP: ± 4

kV; Air:

± 8 kV

B

EN 61000-4-2: 95

Radiated RF

immunity

80 to 1,000 MHz, 3 V/m,

80% AM with 1 kHz sine

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

A

EN 61000-4-3: 96

ENV 50204: 95

Electrical fast

transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

Conducted RF

immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine A

EN 61000-4-6: 97

Voltage dips,

interrupts

0% open, 5 seconds

0% short, 5 seconds

40%, 0.10 seconds

70%, 0.01 seconds

C

C

C

B

EN 61000-4-11: 94

This manual is related to the following products: