Water-level-control sensor check – Southbend STRE-3EZ User Manual
Page 30
S
ERVICE
S
TRATO
S
TEAM
C
OUNTERTOP
S
TEAMER
P
AGE
30
OF
44 O
WNER
’
S
M
ANUAL
1185184
Figure 18
Water-Level-Control Sensor Check
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove the left and right side panels.
3. Remove bottom panel (four screws).
4. Remove insulation cover panel (four nuts).
5. Locate the water-level-control sensor (at the rear edge of the rear element block). Disconnect wires B1 and B2
from the sensor.
6. Place test leads across water-level-control sensor terminals (as shown above) and check for continuity when
the sensor is cool. If no continuity, replace sensor.
7. Reconnect wires and reassemble.