Steamer Not Heating Up, “Power” Light Is Not Lit

DISCONNECT POWER AT CIRCUIT BREAKER

Steamer not heating up, “Power” light not lit.

Test operation of power switch (see page 25). Replace if

necessary. If power switch is OK, replace “Power” light and follow

procedure on page 22.

Disconnect all the heating

cartridges from the contactor.

Measure the resistance across

the leads each cartridge.

Replace any cartridge that

shows either an open or short

circuit.

Cartridges are OK

Is measured resistance

in the range specified on

page 24?

Is measured

voltage 208, 220, or 240

volts?

No

Yes

DISCONNECT POWER AT CIRCUIT BREAKER

Remove right side panel for access.

Reconnect power at circuit breaker.

Turn lever to “ON” position and close door (to actuate door switch).

Check voltage between terminals L1 and L3 on contactor

(see page 26).

Check resistance between heating-cartridge contactor terminals

as described on page 24.

No

Yes