Contactor check – Southbend STRE-3EZ User Manual

Page 26

background image

S

ERVICE

S

TRATO

S

TEAM

C

OUNTERTOP

S

TEAMER

P

AGE

26

OF

44 O

WNER

S

M

ANUAL

1185184

Figure 14

Contactor Check

L1

A

L2

B

L3

C

Actuator

Button

View Looking Down

Behind Contactor

Ohms

No Continuity

Top of

Steamer

1. DISCONNECT POWER AT CIRCUIT BREAKER.

2. Remove right side panel.

3. Depress actuator on top of contactor. Actuator should travel freely and spring back when released.

4. Check for continuity between contacts L1 and A as shown above. There should be no continuity.

5. Repeat Step 4 for contacts L2 and B and for contacts L3 and C.

6. Remove wires B3 and B9 from contactor coil.

7. Place test leads on contactor coil terminals as shown in “View Looking Down” shown above and check

resistance

8. If resistance is not in the range 350 to 425

Ω, replace contactor.

9. Reconnect all wires.