Instructions for the Installer

40

15.2 Burner and nozzle characteristics table

Burner

Rated heating

capacity

(kW)

LPG – G30/G31 28/37 mbar

Nozzle

diameter

1/100 mm

By-pass

1/100

mm

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliaire

1.0

50

30

400

73

71

Semi rapid

1.8

65

33

500

127

125

Triple crown

4.0

100

65

1600

290

286

Burner

Rated heating

capacity

(kW)

NATURAL GAS – G20 20 mbar

Nozzle diameter

1/100 mm

Auxiliaire

1.0

72 (X)

400

Semi rapid

1.8

97 (Z)

500

Triple crown

4.0

135 (K)

1600

15.3 Arrangement of the burners on the hob

BURNERS

1. Auxiliary
2. Semi rapid
4. Triple crown

ø min e max (in cm.)

12 - 14
16 - 24
18 - 26