Sharp AR-M205 User Manual
Page 68
66
TROUBLESHOOTING
B. Misfeed in the fusing area
1
Push gently on both ends of the front
cover.
2
Turn the roller rotating knob in the
direction of the arrow.
3
Carefully remove the misfed paper.
Lower the fusing unit release levers to
allow easier removal. Return the
release levers to their operating
positions.
Be careful not to tear the
misfed paper during
removal.
4
Lift the fusing unit release lever.
5
Close the front cover and side cover.
The misfeed indicator
(
) will go out.
The fusing unit is hot. Do not touch
the fusing unit when removing misfed
paper. Doing so may cause a burn or
injury.
• Do not touch the photoconductive drum
(green portion) when removing the misfed
paper. Doing so may damage the drum and
cause smudges on copies.
• Be careful about unfixed toner on the
misfed paper not to soil your hands or
clothes.
Roller rotating knob
Fusing unit
release lever
Warning
Caution
• When closing the front cover, press on both
ends.
• When closing the side cover, press on the
handle.
• If the misfeed indicator (
) does not stop
blinking, check for torn pieces of paper in
the machine.
Note