beautypg.com

Sharp AR-M205 User Manual

Page 68

background image

66

TROUBLESHOOTING

B. Misfeed in the fusing area

1

Push gently on both ends of the front
cover.

2

Turn the roller rotating knob in the
direction of the arrow.

3

Carefully remove the misfed paper.
Lower the fusing unit release levers to
allow easier removal. Return the
release levers to their operating
positions.

Be careful not to tear the
misfed paper during
removal.

4

Lift the fusing unit release lever.

5

Close the front cover and side cover.

The misfeed indicator
(

) will go out.

The fusing unit is hot. Do not touch
the fusing unit when removing misfed
paper. Doing so may cause a burn or
injury.

• Do not touch the photoconductive drum

(green portion) when removing the misfed
paper. Doing so may damage the drum and
cause smudges on copies.

• Be careful about unfixed toner on the

misfed paper not to soil your hands or
clothes.

Roller rotating knob

Fusing unit
release lever

Warning

Caution

• When closing the front cover, press on both

ends.

• When closing the side cover, press on the

handle.

• If the misfeed indicator (

) does not stop

blinking, check for torn pieces of paper in
the machine.

Note