Calibrating table tilt scale, Notice – Woodstock STEELEX ST1000 User Manual
Page 22
-20-
ST1000 14" Bandsaw
Calibrating Table Tilt
Scale
The pointer on the table tilt scale must be calibrated
in order for the scale reading to be accurate.
To calibrate the pointer on the table tilt scale:
1. Make sure that the blade is tensioned and is
tracking correctly, and that the table is 90˚ to
the blade.
2. Loosen the screw on the pointer (Figure 28),
but do not remove it.
Figure 28. Table tilt scale.
3. Align the tip of the pointer with the 0˚ mark on
the table tilt scale.
4. Tighten the screw on the pointer so that the
pointer is locked in place.
Figure 27. Lateral adjustment of blade guides.
Blade
Gullet
NOTICE
Make sure that the blade teeth will not contact
the guide blocks when the blade is against the
rear support bearing during the cut.
NOTICE
Whenever changing a blade or adjusting ten-
sion and tracking, the upper and lower blade
support bearings and guide-blocks must be
properly adjusted before cutting operations.
1
/
16
"
Blade
Guide
Block
5. Move the guides forward or backward to posi-
tion them laterally, so that the edges of the
blocks are
1
/
16
" behind the blade gullets as illus-
trated in Figure 27.
6. Tighten the thumbscrew on the adjustment
rod.
7. Loosen the thumbscrews that secure the guide
blocks.
8. Adjust the position of the blocks 0.004" away
from the blade.
Note: 0.004" is approximately the thickness of a
piece of paper.
9. Tighten the thumbscrews.