beautypg.com

JVC G2000 User Manual

Page 64

background image

62

2

Loosen the lamp-unit screws, raise
the handle, and pull out the lamp
unit.

Loosen the two screws with a flat-end screwdriver.

Screw

Lamp unit

Handle

Lamp unit

Handle

Screw

Lamp-replacement
opening cover

Be careful not to
damage the claw.

3

Insert the new lamp unit fully
inside and fasten the screws.

Fasten the two screws with a flat-end screwdriver.

CAUTION

• Do not touch the glass surface of the light-source lamp

directly with your hand as well as staining it. If you touch
with a bare hand, stains on your hand may adhere to the
lamp, possibly preventing the lamp from performing as
specified due to a shortened lamp life, a darkened screen,
etc. To handle a new light-source lamp, hold its plastic
part. Never touch the metal part or the front glass
surface.

CAUTIONS

• Install the lamp unit and close the lamp-replacement opening cover correctly; otherwise, a safety switch is activated

to prevent the projector from operating.

• If the claw on the lamp-replacement opening cover is damaged, the projector may not possibly operate. Then, replace

with a new lamp-replacement opening cover.

• After replacing the lamp, be sure to reset the lamp use time (see page 63).

4

Replace the lamp-replacement
opening cover and fasten the
screws.

Fasten the two screws with a flat-end screwdriver.

1

2

Replacing the Light-Source Lamp (Cont.)

Note

• The screws are fitted so that they do not come off the lamp-

unit.

1

2

G2000 p.60-71

99.11.20, 3:30 AM

62