Chapter 3---Service Adjustments

3-6

Model 330, 340SC, 370SC Service Manual

R

328

R

411

R

311

R

211

R

228

R

428

Blue
Vertical
Size

Red
Vertical
Linearity

Blue
Vertical
Linearity

Green
Vertical
Linearity

Green
Vertical
Size

Red
Vertical
Size

R

36

R

R

R

96 139 171

CAUTION!!!

Do not adjust the pots that are shaded! They are

factory adjusted. Do not adjust the Green Vertical

Size or Green Vertical Linearity unless the Green

Yoke or Green CRT has been replaced.

Figure 3-3

Vertical Size and Linearity Controls on the Vertical Deflection Board.

3.4 Vertical Linearity Tracking

If the vertical linearity is not completely linear, use a small slot screwdriver and
adjust the vertical linearity controls on the Vertical Deflection Board (refer to
Figure 3-2).

NOTE:

The Vertical Linearity pots are factory adjusted and will not normally

need adjustment. The Green Vertical Linearity pot (R-211) in particular, should
not need to be adjusted unless the Green Yoke or Green CRT has been replaced.
If the Green Vertical Linearity is off, however, it should be adjusted.

To adjust vertical linearity:

1.

Select Test Pattern 2.

2.

Remove the projector cover.

3.

Remove the electronics module cover.

4.

View Red over Green and position Red (use the POS control and the
arrow keys on the remote) so that the Red lines at the edge match the
Green lines.

5.

Adjust the Red Vertical Linearity pot R-411 so that Red linearity matches
Green.

6.

Repeat the same procedure for Blue (R-311).

7.

Replace the electronics module cover and the projector cover.