beautypg.com

Cv-m50ir, Mode setting – JAI CV-M50IR User Manual

Page 15

background image

- 14 -

CV-M50IR

SW1-1

MSB

SW1-2

SW1-3

LSB

Shutter speed (sec.)

Normal shutter

Ext. trigger shutter

OFF

OFF

OFF

Off

1/60 (1/50)

OFF

OFF

ON

1/100

1/125

OFF

ON

OFF

1/250

OFF

ON

ON

1/500

ON

OFF

OFF

1/1000

ON

OFF

ON

1/2000

ON

ON

OFF

1/4500

ON

ON

ON

1/10,000

Switch no.

Switch function

Mode setting

OFF

ON

1

Shutter data MSB

For shutter speed select.

Refer to shutter table 7.1.3.

2

Shutter data

3

Shutter data LSB

4

Trigger select

Normal

Ext. trigger

5

CCD accumulation

Field accumulation

Frame accumulation

6

Scanning system

2:1 interlaced

Non-interlaced

7

Gamma correction

Gamma = 1.0

Gamma = 0.45

8

Gain

Manual gain

AGC on

7. Mode Setting

Caution on Mode Setting.

Before making any mode or jumper setting turn the power OFF.

7.1.1. SW1 Switch on the Rear Panel
Factory settings for SW1 are with all 8 switches in OFF position.

7.1.2. Table for SW 1 Setting

7.1.3. Table for Shutter Time

Caution on Shutter.

The image can flicker when the illumination is AC powered.
Highlighted parts of the image will show increasing smear at a shorter shutter time.

OFF = <

ON = >

1/50

off

1/100 1/250 1/500 1/1000 1/2000 1/4500 1/10,000

<

<

<

<

<

>

<

>

<

<

>

>

>

<

<

>

<

>

>

>

<

>

>

>

OFF

ON

1
2

3

4

5
6

7

8

GAIN

INTERLACE

TRIGGER

SHUTTER

GAMMA

ACCUMM

Interlaced < > Non-interlaced

Normal < > External trigger

1.0 < > 0.45

Manual < > Auto

Field < > Frame

Seconds

SW1