beautypg.com

Cv-m50ir – JAI CV-M50IR User Manual

Page 10

background image

- 9 -

CV-M50IR

Cautions in the Pulse Width Control Mode.

1. Pulse width control mode is effective only in non-interlaced field accumulation mode.

2. The exposure start may be delayed up to 1H max., when the falling edge of ext. trigger pulse is not

synchronized with the falling edge of ext. HD signal. To avoid this 1H jitter and delay, the falling edge
of the ext. trigger pulse should be synchronized within 4.4 usec. to the HD pulse. It can be the ext. HD
in or the Internal HD out.
See cautions in Edge Pre-select Mode page 7.

3. The ext. trigger input is 75 Ohm terminated as factory setting. (R127 short and SW2-2 on). The

voltage level of the ext. trigger has to be 4.0 Vp-p ± 2.0 V. The duration should be more than 1 H
negative going. >64 µsec. and < 60 msec. The input is AC coupled.

4. If the ext. trigger input and ext. HD input are from a source with TTL level, set SW2-1 and SW2-2 OFF

for non-terminated. SW2-1 for HD signal, SW2-2 for ext. trigger pulse. See “7.2 SW2 on PK8057
Board”.

CV-M50 EIA (Non-interlaced / Field accumulation mode)

CV-M50 CCIR (Non-interlaced / Field accumulation mode)

TRIG

INT VD

EEN

WEN

EXT HD

INT HD

Effective video

Blanking

Blanking

Video out

CCD out

No.10 to 251

Effective pixels

Pulse width control mode (for non-interlace only)

EIA : 1H = 63.5

µs

1H more

1.5H

9H

2H

9H

10H

0.5H

9H

1.5H

1H

TRIG in

1H

20H

242H

20H

Exposure time

Exposure time

0.5H

12.5H

CCIR : 1H = 64

µs

Pulse width control mode (for non-interlace only)

TRIG

INT VD

EEN

WEN

EXT HD

INT HD

Effective video

Blanking

Blanking

Video out

CCD out

No.10 to 251

Effective pixels

1H more

1.5H

7.5H

7.5H

9H

10H

14H

0.5H

7.5H

1.5H

6.5H

7.5H

TRIG in

1H

25H

287H

25H

Exposure time

Exposure time

0.5H

16.5H