John Deere HR-BG5202-NG User Manual
Page 10

0
Operator’s Manual
Preparation
leaK TeSTING
All factory-made connections have been thoroughly tested for gas leaks.
However, shipping and handling may have loosened a gas fitting.
CauTION: TeST all fITTINGS fOR leaKS BefORe uSING
yOuR GaS GRIll.
TeST fOR leaKS eVeRy TIMe yOu dISCONNeCT
aNd ReCONNeCT a GaS fITTING, TeST aTleaST
ONCe a yeaR OR afTeR aNy lONG PeRIOdS Of
TIMe WITHOuT uSe.
dO NOT SMOKe!
NeVeR TeST fOR leaKS WITH a lIGHTed MaTCH
OR OPeN flaMe.
TeST fOR leaKS OuTdOORS.
To test for leaks:
. Check to make sure the burner controls are “OFF”. Extinguish any
open flame or cigarettes in the area.
2. Prepare a soap solution of one part water, one part liquid
detergent.
. Open gas shut off valve.
4. Brush the soap solution on each connection. (Fig. )
5. If your grill is equipped with a side burner or rear burner (Fig. ):
a. Place finger tip over the opening in the orifice at the end of
hose.
b. Turn “SIDE”/“REAR” control to “HI”.
c. Brush soap solution on each connection between orifice and
control valve.
d. Turn “SIDE”/“REAR” control to “OFF”.
6. A leak is identified by a flow of bubbles from the area of the leak.
7. Any leak detected must be sealed before the appliance can be
used.
8. If the leak cannot be sealed, shut off the gas supply and contact
the dealer or the gas company for assistance. DO NOT attempt to
operate the appliance.
Fig.
Fig.
Orfice