STORING GENERATOR
SHORT TERM (1-6 MONTHS):
1. Add gasoline conditioner and stabilizer at the specified
concentration.
2. Run the unit for two (2) minutes to ensure the mixed fuel
is in the entire fuel system. Close the fuel valve and run
the unit until it stops.
3. Remove the spark plug, pour 1-2 teaspoons (5-10cc)
of engine oil into the cylinder, slowly pull the starter
handle 2 or 3 times, reinstall the spark plug and tighten
securely.
4. Clean the exterior surface of the generator and apply a
rust inhibitor.
5. Store the generator in a dry, well ventilated place.
LONG TERM (MORE THAN 6 MONTHS):
1. Add gasoline conditioner and stabilizer at the specified
concentration.
2. Run the generator until the fuel tank and carburetor are
dry. As the engine is beginning to die, move the choke
lever to the choke position.
NOTE: Turn off the idle control to decrease the run time.
3. Remove the spark plug, pour 1-2 teaspoons (5-10cc)
of engine oil into the cylinder, slowly pull the starter
handle 2 or 3 times, reinstall the spark plug and tighten
securely.
4. Clean the exterior surface of the generator and apply a
rust inhibitor.
5. Store the generator in a dry, well ventilated place.
WARNING: FUEL SHOULD BE DRAINED IN A
WELL VENTILATED AREA AND STORED IN A
CONTAINER APPROVED FOR GASOLINE.
STORAGE