John Deere IDLC125-3J User Manual
8l engine model, Standard conditions
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
ENGINE PERFORMANCE CURVE
J
ohn
D
eere
Rating:
Gross Power
Application: Generator (60 Hz)
Target:
125 kWe Standby Market
PowerTech E
TM
6.8L Engine
Model:
6068HF285
180 hp (134 kW) Prime
197 hp (147 kW) Standby
[See Option Code Tables]
Nominal Engine Power @ 1800 RPM
Prime
Standby
HP
kW
HP
kW
180
134
197
147
Generator
Efficiency
%
Fan Power
(6% of Standby)
Power
Factor
Prime Rating
2
Standby Rating
1,2
ISO 8528 G2
Block Load
Capability
hp
kW
kWe
kVA
kWe
kVA
88-92
10.9
8.1
0.8
111-116
139-145
122-128
153-160
100%
Note 1: Based on nominal engine power.
Note 2: kWe / kVA rating assumes 90% efficiency. “Generator Efficiency %” will vary.
- PRIME
O - STANDBY
O)
70
(32)
50
(23)
30
(14)
100
140
180
220
(75)
(104) (134) (164)
Brake Power -- hp (kW)
STANDARD CONDITIONS
Air Intake Restriction................... 12 in.H
2
O (3 kPa)
Exhaust Back Pressure........... 30 in.H
2
O (7.5 kPa)
Gross power guaranteed within + or - 5% at SAE J1995
and ISO 3046 conditions:
77 °F (25 °C) air inlet temperature
29.31 in.Hg (99 kPa) barometer
104 °F (40 °C) fuel inlet temperature
0.853 fuel specific gravity @ 60 °F (15.5 °C)
Conversion factors:
Power: kW = hp x 0.746
Fuel: 1 gal = 7.1 lb, 1 L = 0.85 kg
Torque: N*m = lb-ft x 1.356
All values are from currently available data and are subject
to change without notice.
Notes:
All OEM Gen Set Engine Applications must be pre
screened for torsional vibration compatibility with the
respective alternator end hardware.
OEM Engine Application Engineering will perform this
computer-based analysis work upon request.
Tier-3 Emission Certifications:
Certified by:
CARB; EPA
Ref: Engine Emission Label
a a. June '01
* Revised Data
Curve 6068HF2851800197 .
.Sheet 1 of 2
June 2007
Engine Performance Curves
6068 - Generator
June 2007