Rs-232c communication examples – JVC DLA-RS0 User Manual
Page 55
ENGLISH
55
Getting Started
Preparation
Basic Operation
Troubleshooting
Settings
Others
RS-232C Communication Examples
This section shows the communication examples of RS-232C.
■
Operating command
Type
Command
Description
Connection check
PC→This unit: 1 89 01 00 00 0A
This unit→PC: 06 89 01 00 00 0A
Connection check
Power (On)
PC→This unit: 1 89 01 50 5 1 0A
This unit→PC: 06 89 01 50 5 0A
When power is turned on from standby
mode
Power (Off)
PC→This unit: 1 89 01 50 5 0 0A
This unit→PC: 06 89 01 50 5 0A
When power is turned off (standby mode)
from power-on mode
Input (COMP.)
PC→This unit: 1 89 01 9 50 0A
This unit→PC: 06 89 01 9 50 0A
When video input is set to component
Remote Control
(MENU)
PC→This unit: 1 89 01 5 5 0A
This unit→PC: 06 89 01 5 0A
When the same operation as pressing
the [MENU] button on the remote control
is made
■
Reference command
Type
Command
Description
Power (On)
PC→This unit: F 89 01 50 5 0A
This unit→PC: 06 89 01 50 5 0A
This unit→PC: 0 89 01 50 5 1 0A
When information of power-on mode is
acquired
Input (S-VIDEO)
PC→This unit: F 89 01 9 50 0A
This unit→PC: 06 89 01 9 50 0A
This unit→PC: 0 89 01 9 50 0 0A
When information of S-VIDEO input is
acquired