Permanent connection, Technical specifications, Electrical connection – John Lewis JLBICM 01 User Manual
Page 11
9
Technical specifications
Width 594
mm
Depth 475
mm
Height
378 mm
Capacity of water reservoir
2.5 l
Net weight
28 kg
Gross weight
31 kg
Supply voltage
230 V
Rated power
2000 W
Power absorbed by the heating element
1700 W
Power absorbed by the pump
50 W
Working pressure
12 bar
Fuse 13
A
Electrical connection
Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.
WARNING: THIS APPLIANCE MUSTBE EARTHED.
Should the appliance power supply cable need to be replaced, this must be carried out by a Service Force agent. The
manufacturer declines any liability should this safety measure not be observed.
Before switching on, make sure the electricity supply voltage is the same as that indicated on the applianceÊs rating plate.
The appliance should be fitted with a 13amp plug. The plug should be fitted with a 13amp ASTA approved BS1363/A fuse.
The mains lead of the appliance should be connected as described below. The wires in the mains lead are coloured in
ng code:
accordance with the followi
• Green and Yellow – Earth
• Blue - Neutral
• Brown - Live
In the plug the colours of the wires may not correspond with the markings identified with the
terminals in your plug:
1) Connect the Green and Yellow (earth) wire to the terminal in the plug which is marked with the letter "E" or the
earth symbol or coloured green and yellow.
2) Connect the Blue (neutral) wire to the terminal in the plug which is marked with the letter "N" or coloured black.
3) Connect the Brown (live) wire to the terminal in the plug which is marked with the letter "L" or coloured red.
4) Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over
the outer sheath.
THE PLUG MUST STILL BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN INSTALLED.
THE APPLIANCE SHOULD NOT BE CONNECTED TO THE ELECTRICAL SUPPLY BY MEANS OF AN EXTENSION CABLE
Permanent connection
In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the
electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required
load in compliance with the current electrical regulations.
The switch must not break the yellow and green earth cable at any point.