beautypg.com

Specifications – JBL MPC User Manual

Page 17

background image

16

Specifications

Direct Output Models

Audio Transformer AND Direct Outputs

Electronics

MPC200

MPC300

MPC600

MPC200T

MPC300T

MPC600T

Direct Power Out
4

bridge 1 kHz, 1% THD

1

700 W

900 W

1800 W

700 W

900 W

1800 W

8

bridge 45 Hz–20 kHz, 1% THD

450 W

600 W

1200 W

450 W

600 W

1200 W

2

load/channel

2

, 1 kHz, 1% THD

1

350 W

450 W

900 W

350 W

450 W

900 W

4

load/channel

2

, 45 Hz–20 kHz, 1% THD

225 W

300 W

600 W

225 W

300 W

600 W

Isolated Constant Voltage Out
200V or 140V Bridge:

350 W

500 W

1000 W

100V or 70V/Channel

175 W

250 W

500 W

25V/Channel:

150 W

200 W

400 W

Frequency Response

(bandlimited by built-in highpass filter)

Direct Outputs:

20 Hz–20 kHz ±0.2 dB

50 Hz–20 kHz* 45 Hz–20 kHz**

Isolated Outputs

50 Hz–16 kHz* 45 Hz–16 kHz**

* -3 dB @ 50 Hz, -0.2 dB @ 20 kHz ** -3 dB @ 45 Hz, -0.2 dB @ 20 kHz

Sensitivity (for full output):

0.96V

1.02V

1.0V

0.96V

1.02V

1.0V

Voltage Gain (direct outputs):

35 (31 dB)

40 (32 dB)

56 (35 dB)

35 (31 dB)

40 (32 dB)

56 (35 dB)

Output Circuit Type:

AB

AB

H

AB

AB

H

AB = Class AB+B complementary linear stage H = Class AB+B linear stage with Class H 2-step high-efficiency circuit
Distortion:

SMPTE-IM less than 0.05%

Damping Factor:

Greater than 200 (direct outputs)

Noise:

Less than 100 dB below rated output (20 Hz to 20 kHz)

Input Impedance:

20k ohm balanced, 10k ohm unbalanced

Amplifier Protection:

Short circuit, open circuit, ultrasonic, RF, thermal muting, over-temperature. Stable into reactive or under-impedance loads.

Load Protection:

Turn-on / turn-off muting, DC-fault load grounding relay (MPC300, 300T, 600, 600T) with internal fault fuses.

Power Requirements:

100V, 120V, 220–230V AC, 50–60 Hz (Not user configurable)

Physical:

Controls
Front Panel:

Power Switch

Rear Panel:

Ch 1 & Ch 2 gain controls (11 detents: 0 dB, -2, -4, -6, -8, -10, -12, -14, -18, -24, off); Parallel/Stereo/Bridge

switch (except MPC200 & 200T)

Connectors

Input:

Euro-style detachable header with screw-down terminal for bare wires

Output:

Covered barrier strip for bare wires or spade terminal

Cooling:

Two-speed fan with back-to-front airflow

Net Weight:

14 kg (27 lb)

19 kg (42 lb)

23 kg (50 lb)

18 kg (37 lb)

25 kg (55 lb)

31 kg (67 lb)

Shipping Weight:

17 kg (33 lb)

23 kg (49 lb)

27 kg (58 lb)

21 kg (42 lb)

28 kg (62 lb)

34 kg (75 lb)

Indicators:

CLIP: Red

POWER: Green
PROTECT: Red (except MPC200 and 200T)
SIGNAL: Green (except MPC200 and 200T)

Dimensions (H × W × D)
MPC200T & 200:

89 Ч 483 Ч 455 mm (rack depth 450 mm); 3.5 Ч 19 Ч 17.9 in (rack depth 17.7 in); 2 RU high

MPC300T, 300, 600T, & 600:

133 Ч 483 Ч 455 mm (rack depth 450 mm); 5.25 Ч 19 Ч 17.9 in (rack depth 17.7 in) 3 Rack Units high

Agency Approvals:

UL & CUL approved, CE compliant, and approved by Lucasfilm for THXÒ installations

Optional Accessories:

MP-RRB1: Rear Rack Bracket for 3RU (5.25 in) models (set of 2)

MP-RRB2: Rear Rack Bracket for 2RU (3.5 in) models (set of 2)

1

Typical

2

Both channels drive, 120V 60 Hz mains.

JBL continually engages in research related to product improvement. Changes introduced into existing products without notice are an expression of that philosophy.