Specifications – JBL MPC User Manual
Page 17
16
Specifications
Direct Output Models
Audio Transformer AND Direct Outputs
Electronics
MPC200
MPC300
MPC600
MPC200T
MPC300T
MPC600T
Direct Power Out
4
Ω
bridge 1 kHz, 1% THD
1
700 W
900 W
1800 W
700 W
900 W
1800 W
8
Ω
bridge 45 Hz20 kHz, 1% THD
450 W
600 W
1200 W
450 W
600 W
1200 W
2
Ω
load/channel
2
, 1 kHz, 1% THD
1
350 W
450 W
900 W
350 W
450 W
900 W
4
Ω
load/channel
2
, 45 Hz20 kHz, 1% THD
225 W
300 W
600 W
225 W
300 W
600 W
Isolated Constant Voltage Out
200V or 140V Bridge:
350 W
500 W
1000 W
100V or 70V/Channel
175 W
250 W
500 W
25V/Channel:
150 W
200 W
400 W
Frequency Response
(bandlimited by built-in highpass filter)
Direct Outputs:
20 Hz20 kHz ±0.2 dB
50 Hz20 kHz* 45 Hz20 kHz**
Isolated Outputs
50 Hz16 kHz* 45 Hz16 kHz**
* -3 dB @ 50 Hz, -0.2 dB @ 20 kHz ** -3 dB @ 45 Hz, -0.2 dB @ 20 kHz
Sensitivity (for full output):
0.96V
1.02V
1.0V
0.96V
1.02V
1.0V
Voltage Gain (direct outputs):
35 (31 dB)
40 (32 dB)
56 (35 dB)
35 (31 dB)
40 (32 dB)
56 (35 dB)
Output Circuit Type:
AB
AB
H
AB
AB
H
AB = Class AB+B complementary linear stage H = Class AB+B linear stage with Class H 2-step high-efficiency circuit
Distortion:
SMPTE-IM less than 0.05%
Damping Factor:
Greater than 200 (direct outputs)
Noise:
Less than 100 dB below rated output (20 Hz to 20 kHz)
Input Impedance:
20k ohm balanced, 10k ohm unbalanced
Amplifier Protection:
Short circuit, open circuit, ultrasonic, RF, thermal muting, over-temperature. Stable into reactive or under-impedance loads.
Load Protection:
Turn-on / turn-off muting, DC-fault load grounding relay (MPC300, 300T, 600, 600T) with internal fault fuses.
Power Requirements:
100V, 120V, 220230V AC, 5060 Hz (Not user configurable)
Physical:
Controls
Front Panel:
Power Switch
Rear Panel:
Ch 1 & Ch 2 gain controls (11 detents: 0 dB, -2, -4, -6, -8, -10, -12, -14, -18, -24, off); Parallel/Stereo/Bridge
switch (except MPC200 & 200T)
Connectors
Input:
Euro-style detachable header with screw-down terminal for bare wires
Output:
Covered barrier strip for bare wires or spade terminal
Cooling:
Two-speed fan with back-to-front airflow
Net Weight:
14 kg (27 lb)
19 kg (42 lb)
23 kg (50 lb)
18 kg (37 lb)
25 kg (55 lb)
31 kg (67 lb)
Shipping Weight:
17 kg (33 lb)
23 kg (49 lb)
27 kg (58 lb)
21 kg (42 lb)
28 kg (62 lb)
34 kg (75 lb)
Indicators:
CLIP: Red
POWER: Green
PROTECT: Red (except MPC200 and 200T)
SIGNAL: Green (except MPC200 and 200T)
Dimensions (H × W × D)
MPC200T & 200:
89 Ч 483 Ч 455 mm (rack depth 450 mm); 3.5 Ч 19 Ч 17.9 in (rack depth 17.7 in); 2 RU high
MPC300T, 300, 600T, & 600:
133 Ч 483 Ч 455 mm (rack depth 450 mm); 5.25 Ч 19 Ч 17.9 in (rack depth 17.7 in) 3 Rack Units high
Agency Approvals:
UL & CUL approved, CE compliant, and approved by Lucasfilm for THXÒ installations
Optional Accessories:
MP-RRB1: Rear Rack Bracket for 3RU (5.25 in) models (set of 2)
MP-RRB2: Rear Rack Bracket for 2RU (3.5 in) models (set of 2)
1
Typical
2
Both channels drive, 120V 60 Hz mains.
JBL continually engages in research related to product improvement. Changes introduced into existing products without notice are an expression of that philosophy.