beautypg.com

External trigger. scan mode, Cv-l105 – JAI CV-L105 User Manual

Page 13

background image

CV-L105

6.2.3. External Trigger. Scan mode.
In this mode, the camera requires an EXT TRIG signal to be issued to the camera. The trigger
signal is typical taken from an encoder. The exposure time is equal to the trigger interval. On
the EXT TRIG input positive going edge the ongoing integration period is terminated and charge

is read out. At the same time it starts a new cycle. The exposure time is therefore dependant of
the line rate.
SHUTTER and SCAN parameters has no function here.
The permitted range for the trigger interval is >2120 clk to ∞.
Max scan rate is 14285 lines per second.
Trigger width should be >4 clk.

To use this mode:

Set function:

Trigger

External

Mode

SCAN

SHUTTER value

No function

SCAN value

No function

Clock, Binning and other functions

Input:

Ext. trigger through the LVDS connector

Important notes on using this mode:

-

• It is only recommended to use this mode when there is not change of speed in the object

being scanned. If the speed of the object changes, the exposure time change.

• Do not apply a new trigger before the previous result has been read out. >2120 clk.




30 MHz 1t=33.3 ns

15 MHz 1t=66.6 ns
Value in ( ) is for Binning



Fig. 14. Timing for external trigger scan mode


- 12 -