beautypg.com

Trigger modes, Cv-l105 – JAI CV-L105 User Manual

Page 10

background image

CV-L105

6.2. Trigger modes


Internal Trigger. Scan mode.
The camera will operate continuously with
its internal trigger.

LEN

Data out

Exposure

Exposure time = SCAN value

LEN

Data out

Exposure

Exposure time = SCAN value

The exposure is equal to the scanning time

set by the SCAN parameter via RS-232C only.
SHUTTER parameter has no meaning here.
SCAN value 150 µs through 32.5 ms.


Internal Trigger. Shutter mode.
The camera will operate continuously with
its internal trigger.

LEN

Data out

Exposure

Exposure time

= SHUTTER value

Scan interval = SCAN value

LEN

Data out

Exposure

Exposure time

= SHUTTER value

Scan interval = SCAN value

The scanning time is set by the SCAN

parameter via RS-232C only.
The exposure is set by the SHUTTER
parameter via RS-232C only.
SCAN value 150 µs through 32.5 ms.
SHUTTER value 1 µs through 32.35 ms.


External Trigger. Scan mode.
For every EXT TRIG input the ongoing
integration period is terminated and charge

is read out. At the same time it starts a new
cycle.

LEN

Data out

Exposure

Trigger

Exposure time

LEN

Data out

Exposure

Trigger

Exposure time

The exposure time is therefore dependant of
the line rate.
SHUTTER and SCAN parameters has no
meaning here.
Trigger pulse width (high period) >4 clk. *)
Trigger interval >2120 clk to ∞


External Trigger. Shutter mode.
The exposure time is governed by the low
period of the EXT TRIG signal. Exposure starts
at the falling edge of the EXT TRIG signal and
ends with the rising edge. The integration
time is independent of the line rate.

Data out

Exposure

Trigger

Exposure time

Data out

Exposure

Trigger

Exposure time

SHUTTER and SCAN parameters has no

meaning here.
Trigger pulse width (high period) >4 clk. *)
Exposure time (low period) >2102 clk to ∞

*) 1 clk is 33.3 ns for 30 MHz clock
1 clk is 66.6 ns for 15 MHz clock

Fig. 11. Internal and external trigger modes.

- 9 -