beautypg.com

Internal trigger. scan mode, Cv-l105 – JAI CV-L105 User Manual

Page 11

background image

CV-L105

6.2.1. Internal Trigger. Scan mode.
In this mode, the camera does not require an EXT TRIG signal to be issued to the camera. The
line rate (scan rate) is generated inside the camera. The camera will operate continuously with
its internal trigger.

The exposure time is equal to the scanning time set by the SCAN parameter via RS-232C.
The permitted range for the scan rate is 151 µs to 32.5 ms (corresponds to 6.6 kHz to 30 Hz).
SHUTTER parameter has no function here.


To use this mode:
Set function:

Trigger

Internal

Mode

SCAN

SHUTTER value

No function

SCAN value

151 µs through 32.5 ms

Clock, Binning and other functions

Input:

Important notes on using this mode:

-

• It is only recommended to use this mode when there is not change of speed in the object

being scanned. If the speed of the object changes, the aspect ratio in the vertical
(scanning) direction will change.


LEN

Data out

Exposure

Exposure time = SCAN value

LEN

Data out

Exposure

Exposure time = SCAN value






30 MHz 1t=33.3 ns

15 MHz 1t=66.6 ns
Value in ( ) is for Binning




Fig. 12. Timing for internal scan mode

- 10 -