beautypg.com

Relay alarm, Alarm out – JVC VN-C30U User Manual

Page 22

background image

22

Relay Alarm

When alarm signals are input one after another with an interval of a few seconds,
an interlocked alarm input can be identified and enable another operation.

[Enable/Disable]

Check [Enable] to use the alarm output and [Disable]
to not use it.

[Configuration Items] These items are used to set the signal output from

the alarm output terminal.

• [Momentum]

Set the time period for which the alarm output is to
be continued.

• [Value]

Select whether the [High] or [Low] level signal is
output as the alarm output.

• [Power on Init]

Select whether or not the alarm signal is output from
the alarm output of VN-C30U at the moment it is
turned ON.

* Set the alarm output according to the output destination device.
* After completing alarm configurations, be sure to confirm that the alarm

operations are performed as intended.