beautypg.com

Using the serial communication, External control, Cont.) – JVC DT-V24G1 User Manual

Page 22: 7 using the serial communication

background image

22

7 Using the serial communication

You can control the monitor from a personal computer etc. via the RS-485 or RS-232C terminal.
• Consult your dealer for the details of the external control specification.

Input

terminal

Cable

Terminal

specification

Communication specifications

RS-485

A straight LAN cable

☞ See below

Baud Rate: 4800 bps
Data Bits: 8 bits
Parity: No parity
Stop Bits: 1 bit
Flow Control: No control
Communication Code: ASCII Code

RS-232C

A straight cable with a D-sub
9-pin connector (male for the
monitor, female for the personal
computer etc.)

This is a female terminal.

1Starting the communication:
connection command (!00BCN1Cr)

3Selecting “SDI 1” input (!00BINACr)

5Terminating the communication:
termination command (!00BCN0Cr)

6Monitor’s status (@00BOKCr)

4Monitor’s status (@00BOKCr)

2Monitor’s status (@00BOKCr)

PC, etc.

Example of communication procedures

Monitor

External Control

(cont.)

This is a female terminal.

• The 7th terminal and the 8th terminal are connected.

Pin No.

Signal

1

NC

2

RXD

3

TXD

4

NC

5

GND

6

NC

7

RTS

8

CTS

9

NC

Pin No.

IN terminal signal

OUT terminal signal

1

TXD +

TXD +

2

TXD –

TXD –

3

RXD +

RXD +

4

NC

NC

5

NC

NC

6

RXD –

RXD –

7

NC

NC

8

GND

GND


All commands consist of the following segments.

Header

Monitor ID

Command ID

Function

Data

Cr (0Dh)

On Header
“!”: Operation commands from the personal computer, etc. (

on page 23).

“?”: Reference commands from the personal computer, etc.
“@”: Status returns from the monitor

To start communication, send the connection command from the personal computer etc.
To terminate the communication, send the termination command from the personal computer etc.