beautypg.com

Ut. (a pg. 17), Le ( a pg. 17), Connection of alarm input / output terminals – JVC TK-C625 User Manual

Page 17: Connection of coaxial cables

background image

EN

17

Connections & Installation (continued)

Connection of Alarm Input / Output Terminals

Connect the alarm input/output terminals to external
devices such as sensors and buzzers.

A

Follow the diagram below to loosen and remove the screws
on the two edges of the terminal block.

B

Strip the coating of the alarm signal cable by about 4 mm
before inserting it into the terminal.

C

Turn the screw on the side to fasten the alarm signal cable.

D

Upon fastening the alarm signal cable, re-install the
terminal block that has been dismantled in

A

.

8 Alarm Input Terminal

Connect this terminal to an infrared, door or metallic
sensor, or to a manual switch.
●Input non-voltage contact signal to the alarm input

terminal to prevent internal circuit noises.

●Do not supply voltage.
●Use the menu to set whether to activate alarm when the

contact is short (make) or open (break).

●Ensure that the alarm signal input lasts for at least 200

ms. Otherwise, they may not be recognized as alarm
signals.

8 Alarm Output Terminal

Connect this to alarm devices such as an annunciator,
indicator, lamp or buzzer.
●The alarm output terminal is a photocoupler-insulated

open collector, which turns ON during an alarm.

●As these terminals are provided with polarity. Ensure that

voltage at the + terminal is higher than that at the -
terminal. Application of reverse voltage in this case may
cause the device to break down.

Connection of Coaxial Cables

Connecting an RG-59 coaxial cable.
Strip the tip of the coaxial cable according to the diagram
below.

MEMO

● If an RG-11 coaxial cable is used it cannot be connected directly to

the terminal board. To use such a cable, connect an RG-59 cable to
the camera and then connect the RG-11 cable to the RG-59 cable.

● To increase cable extension, make use of thicker cables or a cable

compensator.

● The maximum extension distance varies according to the system in

use as well as characteristics of the cable.

Rating
Maximum applied voltage : 20 V DC
Maximum drive current : 25 mA

4 mm

A

C

B

Alarm Signal
Cable

A

D

IN

GND

OUT +

OUT −

22 Ω

7mm

17mm

Mesh Wires

Insulation

Tape

Polyethylene

Core Wire

*

*Fold back the mesh wires and secure using an insulation tape to

prevent them from becoming loose and causing a short circuit.