beautypg.com

Installation, Temperature sensor rough-in, Electrical rough-in – Jacuzzi SteamPro User Manual

Page 13: Electrical finish

background image

INSTALLATION

GENERAL INSTRUCTIONS FOR TEMPERATURE CONTROL MODELS

1. Control Cable Rough-in

The low voltage control can be mounted up to 25
feet
from the generator either inside or outside the
steam room, also see #6 optional secondary digital
generator control. String the 25' cable from the
control location through 1/2" holes in the wall studs
or ceiling joists to the generator. Note: Do not staple
through or damage cable. Use factory supplied
cables only. Optional for tile rooms, a 1 gang rough-
in box may be installed at the desired control
mounting location. A mounting plate with proper 2"
diameter hole is included with the control kit. Tile up
to the 2" hole in the mounting plate.

2. Temperature Sensor Rough-in

It is recommended that the sensor be mounted in
the steam room 6" from the ceiling, but not directly
over the steam dispersion head or more than 7 feet
above the floor. String the sensor cable from the
sensor location through 1/2" holes in the wall studs
or ceiling joists to the generator location. Leave 12"
of slack at the sensor location. Note: Do not staple through or damage cable. Use factory supplied cables only.

3. Electrical Rough-in

Size wire for the generator as indicated by the Electrical Information Chart on page 4. Use correct size and type to
meet electrical codes. Leave 4 feet of slack wire at generator location for finish hookup. Connect the generator to a
dedicated circuit breaker. A GFI device is not required by UL. One may be installed if required by local codes or the
owner. A GFI device will tend to nuisance trip due to heater element aging.

4. Electrical finish

Materials (locally available):

- 3/4" Strain relief for supply wire.

A. Route the copper supply wire with appropriate strain relief through the hole marked POWER ENTRY.
B. Connect the supply wires to the terminal block marked L1 and L2.
C. Connect the ground to the ground lug.

6" MIN -

7'

MAX

TEMPERATURE
SENSOR

STEAM
CONTROL

TEMPERATURE
SENSOR
CABLE

WALL

DECORATIVE
CONTROL COVER
PLATE

CONTROL
HOUSING

CONTROL
HOUSING

SEALANT
(MUST FILL GROUT
LINE FOR TILE
WALLS).

CONTROL
HOUSING

DECORATIVE CONTROL
COVER PLATE

CONTROL HOUSING
MOUNTING SCREWS

2" DIAMETER
HOLE IN FINISHED
WALL

MOUNTING
BRACKET

(DO NOT OVER
TIGHTEN)

CONTROL
CABLE

11