Installation, Automatic drain valve installation (optional) – Jacuzzi SteamPro User Manual
Page 10
1.
Apply thread compound sparingly to male threads
on fitting A. (Keep thread compound from entering
the valve.)
2.
Using a backup wrench to hold fitting A, thread
valve assembly onto fitting and tighten. Valve
outlet must point as shown.
3.
Make certain power is disconnected. Remove
top cover.
4.
Remove and discard plug from hole B .
5.
Feed through hole B. Connect to terminal block 2
(TB2) on circuit board.
6.
Locate strain relief bushing C. Snap strain relief
bushing C into hole B.
7.
Replace cover.
INSTALLATION
Automatic Drain Valve Installation (Optional)
Important Note About Tank Drain Selection:
Jacuzzi Whirlpool Bath strongly recommends purchasing and installing the optional Automatic Drain Valve for the
steam generator. This valve prevents standing water from remaining in the tank between uses.
This valve must be installed where the steam generator may be exposed to freezing temperatures, e.g., in seasonal-
use homes. This valve automatically drains the tank when the water has cooled.
POWER ENTRY
HOLE B
BUSHING C
(PROVIDED)
TB2
OPTIONAL AUTOMATIC DRAIN
VALVE ASSEMBLY
FITTING A 1/2 NPT
(PROVIDED)
ALTERNATE VERTICAL
AUTOMATIC DRAIN
VALVE INSTALLATION
8