16.2 north american J-210 Convertible Models

This wiring diagram is used for all J-210 120/240V 60 Hz North American

convertible spa models.

Optional

Ozonator

O3

Standard 3-Wire 120 VAC Connection (60 Hz, 1 Phase, 15A Service)

Use copper conductors ONLY. Wire size must be appropriate per NEC and/or local codes.

WHT

WHT

WHT

WHT

WHT

WHT

BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK

RED

RED

RED

*

RED

*

RED

*

RED

Heater

1.0 kW @ 120 VAC (3-wire connection)

4.0 kW @ 240 VAC (4-wire connection)

Pressure Switch

Hi-limit/Freeze Sensor

Temperature Sensor

J2

J3

F1

20A

250V

SC-20

Main Pump

Spa Light

Transformer

120 VAC

Optional 4-Wire 240/120 VAC Convertible Heater Connection

1. Remove and discard the factory installed GFCI Cord.
2. Move

RED

*

wire from TB1 position #1 to TB1 position #3 as shown below.

3. Permanently connect to the power supply. Use copper conductors ONLY.
Wire size must be appropriate per NEC and/or local codes.
4. If hot tub is to be operated on 30A service, make sure the jumper provided
at location JP1 #1&2 on the circuit board is installed. If hot tub is to be
operated on 40A service, remove the jumper JP1 #1&2 on the circuit board.

HI

LO

J1 Logic Jumper Settings (Factory Defaults Shown)
JP1 1-2 ON = 30A Logic (4-wire 120/240 VAC operation only)
JP1 1-2 OFF = 40A Logic (4-wire 120/240 VAC operation only)
JP1 7-8 ON = °C Temperature Display
JP1 7-8 OFF = °F Temperature Display

This device complies with Part 15 of the
FCC rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful

interference.

2. This device must accept any inteference

received including interference that may

cause undesired operation.

J20

J21

J12

J14

J16

J11

J15

J13

J17

J7

J8

J9

J10

J5

J6

Heater IN

Heater OUT

F1

K5

K7

K8

J1

Control

Panel

THERM

SWITCH

7

5

3

1

8

6

4

2

To circuit board

GRN

TB1

WHT

BLK

1

2

3

1

2

3

GROUND

GRN

TB1

WHT

BLK

GROUND

WARNING, ELECTRICAL SHOCK HAZARD EXISTS! Always remove power to spa before wiring
and/or configuring the circuit board

Move Wire

Hard
Wire
Only

Plug-in
GFCI
Cord (US
Models
Only) OR
Hard
Wire

45