6.0 power requirements

Jacuzzi

®

spas are designed to provide optimum performance and

flexibility of use when connected to the maximum electrical service listed

below. Minor circuit board modifications can be performed to allow your

new spa to accept an electrical service other than the factory operation

setting.

note: Refer to pages 44-47 for circuit board configuration details or

contact your authorized Jacuzzi dealer.

all north american J-270 and J-280 models (60 Hz)

240V/40A*

240V/50A**

240V/60A***

Circuit Breaker (2-Pole):

40A

*

50A

**

60A

***

Number of Wires:

3

3

3

Frequency:

60 Hz

60 Hz

60 Hz

Current Draw:

26A

36A

45A

* In 40A configuration, the heater will not operate while either jets

pump is running in high speed. Note: pump 2 runs only in high

speed.

** In 50A configuration, the heater will not operate while both jets

pumps are running in high speed. This is the factory setting.

Note: pump 2 runs only in high speed.

*** In 60A configuration the heater will operate while both jets pumps

are running in high speed.

all north american J-230 models (60 Hz)

240V/40A*

240V/50A**

Circuit Breaker (2-Pole):

40A

*

50A

**

Number of Wires:

3

3

Frequency:

60 Hz

60 Hz

Current Draw:

26A

36A

* In 40A configuration, the heater will not operate while the jets

pump is running in high speed.

** In 50A configuration, the heater will operate while the jets pump is

running in high speed. This is the factory setting.

13