13.3 optional CD ozone water maintenance system

If you have elected to have your spa equipped with the optional Jacuzzi

CD ozone water purification system you will find that your water stays

fresh and clear with significantly less chemical sanitizer usage. You will

also probably be able to go longer between complete spa drainings.

14.0 error Conditions/error Messages

Your spa has a self-diagnostic control system. The system will

automatically display the following if a problem is detected.

14.1 summer logic (spas with Circulation pump

option)

When the actual spa water temperature reaches up to 2 °F

(1 °C) above the set temperature, the spa goes into “summer

logic.” The 24-hour circulation pump will turn off automatically

to avoid adding additional heat to the water, eventually creating an

overheat condition. This setting is not user-programmable.

note: The summer logic does not take effect until the spa water

temperature reaches 95 °F (35 °C). This condition is more likely in

excessively hot weather. Remember, the spa’s ability to cool is directly

affected by the ambient temperature. An excessively hot ambient

temperature may prevent the spa from cooling down because it’s

fully insulated construction is designed to retain heat and to minimize

operating costs.
14.2 panel Displays Col

Cool Condition - Temperature has dropped 20 °F (11 °C)

below the current set temperature. Jets pump 1, (or

optional circulation pump) and the heater have been activated to bring

the temperature to within 15 °F (8 °C) of the set temperature. No

corrective action is required!

note: This condition is common during first time fill ups or during refills

since tap water is often very cold.

14.3 panel Displays ICe

Freeze Protection - A potential freeze condition has been

detected. No action is required. Jets pump (or optional

circulation pump) and heater will operate to circulate and warm water

through the plumbing until spa is out of DANGER. See “Winterizing”

(page 36).

14.4 panel Displays sn1

Open sensor (heater is disabled) or shorted sensor (spa is

deactivated). The high-limit temperature sensor is not

functioning. Contact your authorized Jacuzzi dealer or qualified service

technician.