Industrial Ethernet Layer 2 Managed Switch – Web Management Manual

April 29, 2008

14

5. Relay Alarm

Managed Switch offer a relay contact output on Terminal Block of the Switch equipment. It is able

to connect to a light, buzzer …etc. warning device and notify system failures immediately.

We also offer the web tool to configure the relay manually. It’s convenient for you to

enable/disable relay warnings since the Switch equipments are far from you.

Relay Output

This function enables you to configure the relay warnings of Power, Link Lose and

Communication Lose.

System Relay Alarm

When alarm occurred, the relay output on the Terminal Block is activated, and System Relay

Alarm is turned ON.

Power Relay Enable

Managed Switch support dual power inputs to implement the power redundancy, and also

support two relay configurations for those two power inputs.

You can tick the “Power1” or “Power2” checkbox to enable the power relay. If power failures

occur, system relay will be activated.

Link Lose

Set relay active if port disconnected, such as, no cable connected; cable break; opposing

device fail.

Communication Lose

Set relay active if port of the ring pair disconnected.