beautypg.com

Recovery time setting – ICP DAS USA MSM-508FCS User Manual

Page 12

background image

Industrial Ethernet Layer 2 Managed Switch – Web Management Manual

April 29, 2008

9

Recovery Time Setting

Recovery Time (Cyber-Ring Protocol)

Recovery time is the duration of connections that from failure occurred to return to normal.

This function allows you to assign the recovery time in millisecond (ms), the variable is from

100ms to 1500ms (1.5 sec).

Factory default is 300ms.

On Cyber-Ring Protocol Mode, user can specify the recovery time manually, and the

Managed Switch will calculate adaptable Hello Time, Forward Time and Max age Time

automatically.

An adequate recovery time is depended on how many Managed Switch are consisted in the

Ring coupling, the more Managed Switch that you have, the more recovery time that you

need.

If the recovery time is not longer enough, the Master LED will keep on flashing

to make a warning.

Hello Time (STP Protocol)

Hello time is the interval time that the Master Switch sends hello messages to Switch nodes

on the Ring network

,

this is for making sure if the Switch nodes and the topology still keeping

healthy.

This setting is only available on STP Mode. Factory default is 4000ms.

You can tune the time to be between 1000 and 10000 in millisecond (ms).

This manual is related to the following products: