beautypg.com

IBM Netcool/OMNIbus Probe for Nortel CNM User Manual

Page 26

background image

Netcool/OMNIbus Probe for Nortel CNM Reference Guide

20

NetcoolIRPManager:

Failed to retrieve

EntryPointIRP object

from security

interface:

The probe has failed to take the
Corba Object of the Security IRP
and narrow it to its specific
type.

Check the value for the
SecurityIrpFtpCommand

property; change this value if
necessary.

Problem while trying

to connect to the IRP

points

The probe found a problem
while connecting to the
AlarmIRP

or

NotificationIRP

points.

Check the values set for the
AlarmIrpName

, and

NotificationIrpName

property; change the values if
necessary.

Failed to ping

notification service

The probe found a problem
while connecting to the
NotificationIRP

point.

Check the values set for the
NotificationIrpName

property; change the values if
necessary.

OperationNotSupported

Exception

The Nortel system doesn’t
support the Notification
IrpSystem.idl

.

Contact the IBM support.

Communication failure

- lost connection to

NoticiationIRP:

CORBA.TRANSIENT

exception raised.

NotificationIRP is

down!

CORBA.OBJECT_NOT_

EXIST exception

raised.

NotificationIRP is

down!

Failed to Connect

Either, the server is

not running, the IOR

is out of date, or

probe cannot reach

remote Server

Cannot proceed.

Shutting down!

The NotificationIRP point
from the Nortel System is not
responding.

Check that the Nortel CNM
system is still running.

Failed to iterate

through resynch

alarms

There was a problem with the
resynchronization process.

Check that the Nortel CNM
system is running correctly.
Check that you have specified the
Resynch

property correctly.

Table 7. Error messages (4 of 4)

Error

Description

Action