4/64 san switch port side leds, 14 4/32 san switch nonport side led patterns – IBM AA-RWF3A-TE User Manual
Page 79

describes the 4/32 SAN Switch nonport side LEDs.
Table 14 4/32 SAN Switch nonport side LED patterns
LED name
LED color
Hardware status
Recommended action
No light
Power supply is not receiving
power or power is off.
Verify that the power supply is on
and seated and the power cord is
connected to a functioning power
source.
Steady green
Power supply is operating
normally.
No action required.
Power Supply
Status
Steady amber
(for more than
5 seconds)
Power supply fault for one of
the following reasons:
Power cable is disconnected.
Power supply is off.
Power supply has failed.
Try the following:
Check the power cable connection.
Verify that the power supply is
powered on.
Replace the power supply.
No light
Fan assembly is not receiving
power.
Verify that the fan assembly is seated
in the switch.
Steady green
Fan assembly is operating
normally.
No action required.
Fan Status
Steady amber
(for more than
5 seconds)
One or more of the fans in the
fan assembly failed or the fan
FRU was disabled by the user.
Verify that the fan FRU is enabled.
If the fan FRU is enabled, the FRU is
faulty and should be replaced.
4/64 SAN Switch port side LEDs
The 4/64 SAN Switch integrates the following port side LEDs:
•
System Status LED
•
Power Status LED
•
Two Ethernet Port LEDs
•
One Port Status LED
•
Port Speed LED for each port on the switch. These LEDs are displayed below
each pair of Fibre Channel ports. The LEDs are located in the array in the same
relative positions as the ports.
on page 80 identifies the LEDs on the port side of the switch.
on page 81 describes the port side LED patterns.
SAN Switch installation guide