beautypg.com

Lpr print queues (lpd protocol), Lpr print queues (lpd – Intermate 100 User Manual

Page 163

background image

Intermate100 and Intermate101 Print Server Administration Manual

163

Services in “Input Control”: LPR Print Queues (LPD Protocol)

22.3.

LPR Print Queues (LPD Protocol)

The print server supports up to 12 LPR queues.

Eight of them are configurable while four are pre-configured.

Each queue is identified by the following three parameters:

1

Name

2

Queue type

3

Where to direct the output of LPR queues See

“Services in

“Input Control”” [page 159]

.

4

Remember to “Save & Cont.” and then “Reboot” to activate.

Pre-

configured

Queues

The four pre-configured LPR queues look like this.

Configurable

Queues

Name:
The “name” fields for the configurable queues have been filled
out with defaults

LPQ1

, .... ,

LPQ8

. If you want to change a

queue name, note that it must consist of maximum 8 ASCII
characters. Check the documentation for your host systems for
syntactical restrictions, or observe the restrictions described on

page 104

.

Queue Type: Choose a queue type from the pull-down list.

Important: If you specify a name in the printing environment

which is not on the [LPR] configuration page, the
print server will use the pre-configured queue named
PAR_B.

Queue Name

Queue Type

Output is directed to

PAR_B

binary (this means no
conversion)

PR0 /Logical Printer 0

PAR_BF

binary plus form feed after the job PR0 /Logical Printer 0

PAR_A

ASCII (also called ASCII transfer.
This includes LF => LF-CR
conversion).

PR0 /Logical Printer 0

PAR_AF

ASCII plus form feed after the job PR0 /Logical Printer 0