beautypg.com

Simm/dimm/rimm memory errors – IBM NETVISTA 2251 User Manual

Page 48

background image

SIMM/DIMM/RIMM memory errors

The following SIMM/DIMM/RIMM error messages are issued by the diagnostic
programs.

Error

FRU/Action

2xx-1y

A memory error was detected in SIMM
socket Y.

Replace the SIMM in the socket identified by
the last digit of the error code.

Re-run the test.

If the same error code occurs again, replace
the system board.

2xx-2y

A memory error was detected in
DIMM/RIMM socket Y

Replace the DIMM/RIMM in the socket
identified by the last digit of the error code.

Re-run the test.

If the same error code occurs again, replace
the system board or where memory is on
the processor card, replace the processor
card.

Corrupt BIOS

Information in BIOS is not as expected.

Not able to find expected DMI information
from BIOS.

Memory controller chipset vendor ID does
not match expected value.

Reflash the BIOS.

Perform boot block recovery.

Replace the system board.

Test aborted by user

Restart test.

Note:

Y is the SIMM/DIMM/RIMM socket number. Use the System Board Layout
section in the latest Hardware Maintenance Manual (HMM) to reference the
memory sockets.

40

Hardware Maintenance Manual

This manual is related to the following products: