IBM NETVISTA 2251 User Manual
Page 64
Diagnostic Error Code
FRU/Action
086-196-XXX
Mouse Port interface test halt, error
threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
086-197-XXX
Mouse Port interface test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
086-198-XXX
Mouse Port interface test aborted
1.
If a component is called out, make sure it
is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″
section
086-199-XXX
Mouse Port interface test failed, cause
unknown
1.
Go to the
″Undetermined problems″
section
2.
Flash the system and re-test
3.
Replace component under function test
089-000-XXX
Microprocessor Test Passed
1.
No action
089-XXX-XXX
Microprocessor failure
1.
Microprocessor(s)
2.
System board
089-195-XXX
Microprocessor Test aborted by user
1.
Information
2.
Re-start the test, if necessary
089-196-XXX
Microprocessor test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
089-197-XXX
Microprocessor test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
089-198-XXX
Microprocessor test aborted
1.
Flash the system and re-test
2.
Go to the
″Undetermined problems″
section
089-199-XXX
Microprocessor test failed, cause unknown
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Go to the
″Undetermined problems″
section
3.
Flash the system and re-test
4.
Replace component under function test
170-000-XXX
Voltage Sensor(s) Test Passed
1.
No action
170-0XX-XXX
Voltage Sensor(s) failure
1.
Flash system
2.
System board
56
Hardware Maintenance Manual