Diagnostic Error Code
FRU/Action
018-195-XXX
PCI Card Test aborted by user
1.
PCI card
2.
Information
3.
Re-start the test, if necessary
018-196-XXX
PCI Card test halt, error threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
018-197-XXX
PCI Card test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
018-198-XXX
PCI Card test aborted
1.
Make sure the component that is called
out is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″
section
018-199-XXX
PCI Card test failed, cause unknown
1.
Go to the
″Undetermined problems″
section
2.
Flash the system and re-test
3.
Replace component under function test
018-250-XXX
PCI Card Services error
1.
PCI card
2.
Riser card, if installed
3.
System board
020-000-XXX
PCI Interface Test Passed
1.
No action
020-0XX-XXX
PCI Interface error
1.
PCI card
2.
Riser card, if installed
3.
System board
020-195-XXX
PCI Test aborted by user
1.
Information
2.
Re-start the test, if necessary
020-196-XXX
PCI test halt, error threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
020-197-XXX
PCI test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
020-198-XXX
PCI test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″
section
Chapter 6. Symptom-to-FRU Index