Installation

BLE*/* Installation and Operation Manual

9

Check the ac voltage setting (jumper J1, Figure 2-6).

J1 position

Description

LO

The voltage must be greater than 38 Vac as read with a true rms voltmeter or 42 Vac
when using a conventional, average reading, ac voltmeter.

HI

The voltage must be greater than 55 Vac when read with a true rms voltmeter or 61
Vac when using a conventional, average reading, ac voltmeter.

10

Check the dc voltage. Verify that it is between 23.6 V and 24.4 V and re-install the input
pad.

11

If necessary, rebalance the amplifier following the instructions in Section 3, “Amplifier
Setup.”

12

Check the tightness of the electronics chassis cover screws (10 to 12 in-lbs.) and electronics
chassis hold-down bolts (18 to 22 in-lbs.).

13

Check the condition of the RF and weather gaskets and replace them if necessary. If needed,
also apply a light coating of silicone grease.

14

Close the housing and use a torque wrench to sequentially and progressively tighten the
housing bolts to a final torque of 6 ft-lb in the sequence specified on the housing cover and
illustrated in Figure 5-2.

Figure 5-2