Housing, Ble*/* installation and operation manual, Figure 2-3 ble-hsg/15 housing and dimensions – Motorola BLE*/* User Manual
Page 14
Overview 2-3
BLE*/* Installation and Operation Manual
Housing
The BLE*/* is furnished in a BLE-HSG/15 aluminum housing that protects the electronics from
weather and dissipates internally generated heat.
Figure 2-3 illustrates the BLE-HSG/15 housing and provides its dimensions:
Figure 2-3
BLE-HSG/15 housing and dimensions
10.6
8.0
4.7
A
S
SE
MBLE
D
I
N
M
E
X I C
O
4
2
6
3
1
5
Coaxial cable connections to the housing are made using conventional 5/8 inch
× 24 threads
per-inch stinger-type connectors. Four port plugs in the cover enable access to internal test
points without opening the housing.
The BLE-HSG/15 differs from the housing of the 10A BLE (model BLE-75SH and BLE-75JH)
and the JLX series of line extenders. However, you can upgrade the 10A BLE and the JLX
series of line extenders to the 15A BLE*/* using the existing housing. To upgrade from 10A to
15A, use the BLE-15A platform assembly kit (P/N 951941-006-00). The BLE-15A kit contains
15A platform assemblies. As an alternative to the kit, you can order the current BLE*/*
electronics module configured as a 10A unit (see Fig.2-2 BLE*/* Configurator, AC Current
Capability).
Two messenger clamps are located in the side of the housing (Figure 2-5) and are secured with
5/16 inch
× 24 threads-per-inch stainless steel bolts. The bottom of the housing also contains two
5/16
× 24 threaded holes located on the vertical center-line separated by four inches
center-to-center. Use these holes and the bolts from the messenger clamps for pedestal and
surface-mounting installations.