beautypg.com

Loading and installation, 1 mounting/removal of qa6adp – MITSUBISHI ELECTRIC QA6ADP User Manual

Page 12

background image

11

5. LOADING AND INSTALLATION


5.1 Mounting/Removal of QA6ADP

(1) Mounting of the QA6ADP

The following shows procedures for mounting the QA6ADP on the
extension base unit.

Mount a board fixing screw of the QA6ADP
to a screw hole (A) at top left of the board.

Connect an extension base unit mounting
connector of the QA6ADP to the IN side of
an extension connector of the extension
base unit.

Tighten the adapter module mounting

screws of the QA6ADP at two parts

(top and bottom), placing a mounting guide.
Mount an upper mounting screw to a

board fixing screw (at top left) of the

extension base unit.

Mount a lower mounting screw to the
adapter module mounting bracket.

In case of the A5 B, connect the
disconnected lead of the FG terminal
(right side).

Connect the Q series extension cable to the
QA6ADP and the upper/lower base unit.

Disconnect the A series extension cable
from the extension base unit.

Remove a base cover from the extension
base unit.

Set the stage number setting connector of
the extension base unit.

In case of the A5 B, disconnect a lead of
the FG terminal (right side).

Among screws fixing a board of the
extension base unit, remove two at the
left. (Screws A and B shown in the figure.)

Set the stage number setting connector of
the QA6ADP. (The setting should be same
as that of the stage number setting
connector of the extension base unit.)

Completed

A)

B)

QA6ADP

Board fixing screw

Adapter module

mounting

bracket

Mounting

guide

Adapter module

mounting

screw

Adapter module

mounting screw

Extension

base unit IN

side connector

Utilize a mounting bracket fixing screw to
mount the adapter module mounting
bracket of the QA6ADP into a screw hole
(B) at the bottom left of the board.

Mounting bracket