Multi-Tech Systems MT4X56USB User Manual
Page 44

MultiModemUSB User Guide
MT4X56USB
44
Command:
&Gn
V.22bis Guard Tone Control
Values:
n = 0, 1, or 2
Default:
0
Description:
&G0
Disable guard tone.
&G1
Set guard tone to 550 Hz.
&G2
Set guard tone to 1800 Hz.
Note: The &G command is not used in North America.
Command:
&Jn
Auxiliary Relay Control
Values:
n = 0
Default:
0
Description:
&J0
The auxiliary relay is never closed.
&J1
Not supported—responds ERROR.
Command:
&Kn
Flow Control Selection
Values:
n = 0, 3, or 4
Defaults:
3
Description:
&K0
Disable flow control.
&K3
Enable CTS/RTS hardware flow control.
&K4
Enable XON/XOFF software flow control.
Command:
&Mn
Communications Mode
Values:
n = 0
Defaults:
0
Description:
&M0
Asynchronous mode.
&M1
Not supported—responds ERROR.
Command:
&Qn
Asynchronous Communications Mode
Values:
n = 0, 5, 6, 8, or 9
Default:
5
Description:
&Q0
Asynchronous with data buffering. Same as \N0.
&Q5
Error control with data buffering. Same as \N3.
&Q6
Asynchronous with data buffering. Same as \N0.
&Q8
MNP error control mode. If MNP error control is not established, the modem falls back according
to the setting in S36.
&Q9
V.42 or MNP error control mode. If neither error control is established, the modem falls back
according to the setting in S36.
Command:
&Sn
Data Set Ready (DSR) Control
Values:
n = 0 or 1
Default:
0
Description:
&S0
Force DSR always high (on).
&S1
Let DSR go high only during a connection.
Command:
&Tn
V.54 Test Commands
Values:
n = 0, 1, 3 or 6
Default:
None
Description:
&T0
Abort. Stop any test in progress.
&T1
Local analog loopback test.
&T3
Local digital loopback test.
&T6
Remote digital loopback test.
Note: To stop a test, you must use the escape sequence (+++AT) before typing AT&T0.
Command:
&V
Display Current Settings
Values:
n/a
Description:
Displays the active modem settings, including the callback security settings if callback security is
enabled. If the setup password has been entered, it also displays the callback security passwords.