South african notice – Multitech MULTI MODEM II MT5600BA User Manual
Page 90

A Regulatory Compliance
84
MultiModemII User Guide
• There shall be no more than 10 call attempts to the same number within any
30-minute period for any single manual call initiation, and
• The equipment shall go on-hook for a period of not less than 30 seconds be-
tween the end of one attempt and the beginning of the next attempt.
For automatic calls to different numbers:
• The equipment shall be set to ensure that automatic calls to different num-
bers are spaced such that there is no less than 5 seconds between the end of
one call attempt and the beginning of another.
For automatically answered incoming calls:
• The equipment shall be set to ensure that calls are answered between 3 and
30 seconds of receipt of ringing.
8. For correct operation, total of the RNs of all devices connected to a single line at
any time should not exceed 5.
South African Notice
This modem must be used in conjunction with an approved surge protection device.