4 at commands, s-registers, and result codes, Multimodemii user guide – Multitech MULTI MODEM II MT5600BA User Manual
Page 52

4 AT Commands, S-Registers, and Result Codes
46
MultiModemII User Guide
Command:
**
n
Flash Memory Download
Values:
n = 0, 1, or 2
Description:
**0
Initiate download to flash memory at the last sensed speed.
**1
Initiate download to flash memory at 38.4K bps.
**2
Initiate download to flash memory at 57.6K bps.
Command:
*B
View Numbers in Blacklist
Values:
n/a
Description:
If blacklisting is in effect, AT*B displays a list of numbers for
which the last call attempted in the previous two hours failed.
Permanently forbidden numbers as defined by country re-
quirements do not appear in this list. If no numbers are black-
listed, only the OK result code is displayed.
Command:
*D
View Delayed Numbers
Values:
n/a
Description:
AT*D
displays a list of delayed numbers, as defined in the *B
command, together with their delay times. If no numbers are
delayed, only the OK result code is displayed.
Command: #CBNy=[-]x Store Callback Number
Values:
y = 01–30
x = dialing string
Default:
None
Description:
Stores the callback dialing string x in memory location y. The
dialing string can include the digits 0 through 9 and any of the
following characters: #, *, comma (,), semicolon (;), W, A, B, C,
and D. Up to 30 characters can be used. Example:
AT#CBN01=9,16127853000
. If the optional - character precedes
the dialing string, and the caller appends the same character to
the password, the caller is immediately connected, and the
hangup and callback are skipped.
Command: #CBPy=x Store Callback Password
Values:
y = 01–30
x = password (6–10 characters)
Default:
None
Description:
Stores callback security password x in memory location y. The
password must have 6 to 10 characters. Example:
AT#CBP01=gilgamesh
.
Note: